ACEY-BCT560-64HP Li-Ion Battery Tester is mainly used to test the voltage, capacity and other parameters of the battery formation and capacity grading stages, and to classify the battery and perform data analysis and upload and share based on the test results. It is suitable for cylindrical, prismatic and polymer battery testing.
Brand :
ACEYItem No. :
ACEY-BCT560-64HPCustomization :
OEM&ODM AvailableOrder(MOQ) :
1 SetCompliance :
CE CertifiedPayment :
T/T, L/C, PayPal, West Union, Alibaba Trade Assurance, EtcWarranty :
One Year Warranty With Lifetime SupportProduct Origin :
ChinaPackage :
Internal: Anti-Collision Protectio, External: Plywood CaseShipment :
By Air, Sea, Express, etc.Product Description
ACEY-BCT560-64HP battery cell formation equipment has an energy-saving feedback function, which can effectively recycle energy during operation, greatly reduce energy consumption, and achieve high efficiency and energy saving. It supports the testing and evaluation of different types of batteries, whether cylindrical batteries, prismatic batteries or polymer batteries, and can measure their voltage and capacity and other parameters with extremely high accuracy, providing reliable data support for battery production, research and development, and quality control.
Equipment features
1. Single point independence, each battery has a completely independent constant current and constant voltage source, stable and impact-free.
2. The equipment is controlled by STM32 single-chip microcomputer and connected to the computer. It can save all test data and curves, and can also be directly operated through the equipment keyboard to set the process to complete the test and sort.
3. Real-time detection and display of the status of each battery. If there is an abnormality, the channel will stop working and the indicator light will be on.
4. It has a power-off protection function, and can continue to run the original workflow after a call.
5. The power tube uses a field effect tube, which is suitable for batteries with lower voltage discharge, such as lithium iron phosphate batteries.
6. The graphical operation interface is adopted, which is intuitive and clear. It displays the voltage, current, time, capacity and other data of each battery at the same time, and can set different colors to display the corresponding working status and abnormal conditions.
7. The equipment accuracy is 0.05%, the data recording time is 1 second/time, and the stability is high.
8. The software is powerful and the human-machine interface is friendly.
9. The four-wire test interface ensures high measurement accuracy.
10. Modular design concept, easy to maintain.
11. Clamp assembly on the left, power assembly on the right.
Note: It is recommended that users equip each computer with a UPS power supply to prevent damage to the computer or data during a power outage; each computer can be connected to a maximum of 10 devices to avoid affecting the computer operation.
Compatible Battery
Cylindrical Battery | |
Diameter | 32-60MM |
Length | 80-160mm |
Prismatic Battery | |
Length | 80-220MM |
Thickness | 20-70mm |
Height | 80-220MM |
Tab spacing | 60-150MM |
Polymer Battery | |
Designed according to the battery information provided by customers |
Main technical parameters
Equipment structure | |
Number of Device Channels | The whole machine has 64 channels |
Chassis Color | Standard gray/gray black (customizable) |
Fixture form | Flat Head Clamp & Alligator Clip |
Channel Control Mode | Each battery has its own independent constant current and voltage source, which is stable and shock-free. It can start, stop, pause, continue and protect. |
Each channel has independent constant voltage and constant current hardware control circuit. | |
The accuracy of charging current and discharging current of each channel can be automatically calibrated by software. | |
Working power supply | Three-phase 5 wire system AC380V ± 10%,50HZ |
power factor | 0.99 @ 220VAC, full load, grid THDu ≤ 2% |
Current harmonic | <5% @ 220VAC, full load, grid THDu ≤ 2% |
Power Department Efficiency Index | Charging ≥ 80%, discharging ≥ 70% |
Working power consumption | ≤ 24KW |
Battery temperature monitoring | -10~70 ℃ adjustable |
Equipment failure rate | <1% |
Heat dissipation mode | Natural air intake, upward exhaust |
Power component protection function | Grid voltage overrun protection |
Power grid frequency overrun protection | |
Channel Parameters | |
Voltage measurement range | DC 0~5V |
Battery voltage range | Charge DC 0~4.5V; Discharge DC 4.5~2V |
Constant voltage range | DC 2~4.5V |
Voltage accuracy | ±(0.5 ‰ reading +0.5 ‰ full degree) |
Voltage control resolution | 1mV |
Voltage sampling resolution | 1mV |
Current range | Charge DC 120mA ~ 60A; Discharge DC 120mA ~ 60A |
Current accuracy | ±(0.5 ‰ reading +0.5 ‰ full degree) |
Current control resolution | 1mA |
Current Sampling Resolution | 1mA |
Current rise time (90% load) | ≤ 50MS |
Channel startup time (90% load) | ≤ 50MS |
Product Display