ACEY-BCT530-128P-25C Thermostatic prismatic battery charge discharge test system is used to test the capacity of prismatic battery cells by cyclic charging and discharging. Box type thermostatic structure, temperature uniformity inside the box 25±2℃.
Brand :
ACEYItem No. :
ACEY-BCT530-128P-25CCustomization :
OEM&ODM AvailableOrder(MOQ) :
1 SetCompliance :
CE CertifiedPayment :
T/T, L/C, PayPal, West Union, Alibaba Trade Assurance, EtcWarranty :
One Year Warranty With Lifetime SupportProduct Origin :
ChinaPackage :
Internal: Anti-Collision Protectio, External: Plywood CaseShipment :
By Air, Sea, Express, etc.
Product Description
ACEY-BCT530-128P-25C Thermostatic prismatic battery charge discharge test system is used to test the capacity, cycle life, internal resistance, energy density, temperature characteristics and other parameters of the battery, so as to evaluate the performance and reliability of the battery. This test cabinet adopts the energy-saving technology to feed the energy released by the battery back to the power grid, so as to realize the energy-saving, efficient and reliable test process.
System Characteristics
Structure


Structure And Working Principle
Technical Parameters
| Number of equipment channels | The whole machine has 128chs |
| External dimension | L2054mm*W940mmH2298mm(subject to actual) |
| Case color | Standard (customizable) |
| Clamp type | Flat head clamp (optional with crocodile clamp) |
| Clamp spring | 81mm |
| Support battery specifications | Length70mm-210mm;Width15-70mm;Height 80mm-230mm |
| Lug center distance 40-150mm. | |
| Channel control mode | Each channel can be started, stopped, suspended, continued and protected independently. |
| Each channel has independent constant voltage and current. Hardware control circuit | |
| The accuracy of charging current and discharging current of each channel can be calibrated automatically by software | |
| Working power supply | Three phase five wire AC380V土10%, 50Hz |
| Power factor | ≥0.99,THDu ≤2% |
| AC current distortion rate | ≤2% |
| efficiency of the whole machine | Charge≥80%, discharge≥70% |
| Power consumption work | ≤23KW |
| Equipment failure rate | <1% |
| Work environment | Temperature -10~40°C. Relative humidity 80% |
| Constant temperature function | Inside the box 25±2℃ |
| Temperature control function | The temperature reaches the preset value before running the work step process. |
| Power component protection function | 1. Grid voltage overrun protection |
| 2. Grid frequency overrun protection | |
| Heat dissipation mode | Natural wind in, upward exhaust |
| Voltage measurement range | DC 0~5V |
| Battery voltage range | Charge DC 0~4.5V; discharge DC 4.5~2V |
| Constant voltage range | DC 2~4.5V |
| Voltage accuracy | ±(0.05% reading + 0.05% full), resolution ratio 1mV |
| Voltage Control Resolution | 0.1mV |
| Voltage Sampling Resolution | 0.1mV |
| Voltage stability | ≤(±1mA) |
| Current range | Charge DC300mA~30A; Discharge DC 300mA~50A |
| Current accuracy | ±(0.05% reading + 0.05% full), resolution ratio 1mV |
| Current Control Resolution | 0.1mA |
| Current Sampling Resolution | 0.1mA |
| Current rise time (90% load) | ≤50MS |
| Channel start-up time (90% load) | ≤50MS |
| Current stability | ≤(±1mA) |
| Control mode | Computer control, can control the whole cabinet with scanning function |
| Communication mode | 485s port communication (port rate 57600)/ TCP |
| Process settings | Up to 32 steps and 256 cycles can be set |
| Charging mode | Constant current; constant pressure; constant current & pressure |
| Charging cut-off conditions | Voltage, current, time, capacity, - △ v |
| Discharge mode | Permanent flow, constant power, constant resistance |
| Discharging cut-off conditions | Voltage, time, and capacity |
| Protection function | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power off protection, data breakpoint recovery |
| Time frame | 0~3000 min / step in min |
| Time accuracy | ≤±0.1% |
| Sampling inspection cycle | 1s-60s optional |
| Battery sorting | Divide according to capacity, time, open-circuit voltage, discharge platform, etc. |
| Data processing | Can record voltage, current, time, capacity etc, automatically calculate constant current charging ratio, capacity loss, discharge efficiency, average voltage, median voltage, provide data curve and cycle diagram; can output text, excel, word or mdb format data file |
| Basic function of software | 1. The software supports various connections, such as manual pause continuation, software shutdown continuation, power outage, disconnection in equipment communication, abnormal stop continuation; |
| 2. Support bar code scanning, scanning one-dimensional code, QR code, channel jump scanning, loading scanning and other scanning methods; | |
| 3. Local test detailed data storage, can view the current test data and historical data of each channel at any time, have data and curve corresponding two ways, and support excel report in single or batch form, and can set the test end automatic data export according to the need. | |
| 4. Support capacity sorting, and grade the battery sorting; | |
| 5. Support the qualified judgment after the test, and judge the pass / ng results according to the specified cycle capacity, voltage, time and other information; | |
| 6. Support various step protection and global voltage, current, temperature abnormal protection, and abnormal alarm, support battery pack overcharge, overdischarge protection test; | |
| 7. Support channel parallel (according to equipment); | |
| 8. Support unit conversion; | |
| 9. Support database server background storage or MES docking; | |
| 10. Software offline protection; |
Product Display



*Related Products